ProductsAnesthesia & Respiratory Monitors

8500H POET® IQ

Overview

Criticare’s Poet® IQ Anesthetic Gas Analyzer pairs with the nCompass™ Patient Monitor, to provide a unique combination of leading edge vital signs technology and anesthesia gas monitoring in a compact, modular system.

The Poet® IQ automatically identifies and quantifies inspired and expired O2, CO2, N2O, and five anesthetic agents. The system’s reliable performance, ease of use, flexible design, and affordable cost make it the ideal monitoring solution for anesthesia applications in hospitals and surgical centers.

Features

  • State-of-the-art non-dispersive infrared (NDIR) technology identifies and measures five anesthetic agent gases: Halothane, Enflurane, Isoflurane, Desflurane and Sevoflurane
  • Automatic or manual modes for agent detection
  • Breath-by-breath O2, CO2 and N2O monitoring
  • Adjustable flow rates: 100, 150 and 200 ml/min
  • Mixed agent identification
  • Accuracy not affected by alcohol or ketones
  • Fast warm-up time ensures full accuracy within minutes

Options

Part number Description
8500H Poet IQ 8500H Anesthetic Gas Monitor

Each product comes with (5) water traps, (5) sampling lines, (5) endotracheal adapters, (1) scavenging kit and (1) user manual on CD-Rom.

Specifications

 

GAS MONITORING
Method: Sidestream; Non-dispersive infrared (NDIR)
Identified Gases: Halothane, Enflurane, Isoflurane, Desflurane, Sevoflurane, O2, CO2, N2O
Concentration Units: Vol%, Torr, kPa, mmHg
Flow Rates: 100, 150 or 200 ml/min

 

AGENT DETECTION
Measurement Range: Halothane: 0 to 10%, Enflurane: 0 to 10%, Isoflurane: 0 to 10%, Desflurane: 0 to 20%, Sevoflurane: 0 to 10%, CO2: 0 to 12.5%, N2O: 0 to 99%, O2: 0 to 100%
Measurement Accuracy: Agents: ±0.1% abs. + 4% of reading, CO2: ±0.2% abs. or 4% of reading, N2O: ±1.5% abs. + 4% of reading, O2: ±3 vol% (0 – 90%), ±4 vol% (91 – 99%)
Time to Detect Agent: < 15 seconds @ 200 ml/min
Agent Detection Resolution: 0.1 vol%
Mixed Gas Threshold: 0.2 vol% +10% of total concentration
Maximum Cuff Pressure:  Adult/Pediatric:
300 mmHg; Neonate: 150 mmHg
Rise Time: Agents: 450 msec, CO2: 350 msec, N2O: 400 msec, O2: 600 msec

 

RESPRIATION RATE
Range:  1 to 60 Br/min
Accuracy: ±2 Br/min or 2% of reading

 

SYSTEM FEATURES
Occlusion Clearing: Automatic
Auto Zeroing: Occurs 30 to 60 minutes
Duration: 3.0 to 7.0 seconds. Manual user calibration not required. Temperature stabilized optical assembly. Auto-calibration; verification recommended once per year.
Warm-up Time: 1 minute to first waveforms; <20 minutes to full accuracy
Alarm Characteristics: EN 475, Adjustable; with audible and visual indications from the patient monitor.
Alarm Levels: High, Medium, Low, Informational
Alarm Modes: Adult/Pediatric/Neonate; High and low limit settings for each mode.

 

TRENDS
Memory: 24 hours of stored data in patient monitor
Display: Tabular, Graphical

 

DISPLAY
Connection: Connects to nCompass ™ 8100H Series patient monitors

 

LANGUAGES
Consultation: Consult with sales or customer service for available language co

 

SYSTEM OUTPUTS
System Configuration: Modular design with bi-directional communication, via cable, to the host monitor.
Waveform Output: Halothane, Enflurance, Isoflurane, Desflurane, Sevoflurane, CO2, N2O, O2
Output Data: Inspired and end-tidal gas concentrations; continuous real-time gas concentrations; respiratory rate (elapsed time since last breath); agent identification (primary agent and mixed agents); system information

 

POWER REQUIREMENTS
Voltage: 12 VDC, typically receives power from host monitor
Power Consumption: 6W peak, 3W typical

 

MECHANICAL
Weight: 5.9 lbs. (2.7 kgs.)
Size: Height: 4.0 in (10.2 cm)
Width: 14.0 in (35.6 cm)
Depth: 10.8 in (27.3 cm)

 

ENVIRONMENTAL
Operating Temperature: 59° to 95°F  (15° to 35 °C)
Storage Temperature: 23° to 122°F  (-5° to 50 °C)
Operating/Storage Humidity: 15% to 95%, noncondensing
Altitude: -1,000 ft to 10,000 ft  (-300 m to 3,000 m)

 

CLASSIFICATION
Medical Device: Class II Equipment (IIb EU)
Electrical Protection: Class I Equipment
Degree of Protection: Type CF, Defibrillator-Proof
Protection Against Ingress: Ordinary

 

AVAILABLE CONFIGURATIONS
8500H Standard

 

Resources

OFFICE MANAGEMENT SOFTWARE COMPATIBILITY – CSI products are compatible with the following OMS products below. Contact software provider to confirm compatibility with specific configurations of Criticare monitors.

Contact Customer Service for details: 1-800-458-4615 (USA) 1-262-798-8282 (International)

Contact

U.S. CORPORATE HEADQUARTERS

333 Strawberry Field Rd Suite 11

Warwick, RI ,02886

T : 800 – 486 – 3849

Hours: 8:30 am to 5:30 pm Eastern Time

Accessories

Learn More

  • This field is for validation purposes and should be left unchanged.