ProductsPatient Monitors

nCompass 8100H Series

Overview

Focus on your patients, not your monitor. The nCompassTM patient monitor is the perfect choice for busy departments demanding accurate, reliable performance.

The nCompassTM can monitor adult and pediatric patients in virtually every department. The innovative user interface features simplified menus and dedicated function keys for timely setups. The big, bright display with large numerics can be easily seen from across the room.

Features

  • Standard features: ECG with Arrhythmia and ST Analysis, ComfortCuff® NIBP, DOX® SpO2, Heart Rate, Temperature, Respiration and Nurse Call interface connection.
  • Optional features: End-tidal and inspired CO2, IBP and integrated printer.
  • Optional CO2 monitoring incorporates CSI’s patented water trap design with full occlusion clearing.
  • Mini-Trends display of condensed tabular vital signs data to show recent monitoring activity.
  • Compatible with popular Electronic Medical Records (EMR) systems for both large and small offices.
  • Easy to read 12.1 inch touchscreen display.
  • Easy to learn, easy to use interface with simplified menus and dedicated function keys.
  • Mounts quickly and easily to walls and rollstands.
  • Interfaces with the Poet® IQ 8500H agent gas analyzer for anesthesia monitoring.

Options

Part Number Description
81H000XD Base configuration including ECG with Arrhythmia and ST Analysis, ComfortCuff® NIBP, DOX® SpO2, Heart Rate, Temperature, Respiration and Nurse Call interface connection.
81H000PD Base with Printer
81H001XD Base with CO2
81H001PD Base with CO2 and Printer
81H010XD Base with 1 Channel IBP
81H010PD Base with 1 Channel IBP and Printer
81H011XD Base with 1 Channel IBP and CO2
81H011PD Base with 1 Channel IBP, CO2 and Printer
81H030XD Standard with 3 Channel IBP
81H030PD Standard with 3 Channel IBP and Printer
81H031XD Standard with 3 Channel IBP and CO2
81H031PD Base with 3 Channel IBP, CO2 and Printer

Each monitor includes (1) SpO2 sensor, (1) NIBP hose, (1) child/small adult NIBP cuff, (1) adult NIBP cuff, (1) large adult NIBP cuff, (1) ECG cable with set of electrodes, (1) rechargeable battery, (1) power cord, and (1) user manual on CD-Rom.

CO2 units also include: (5) water traps, (5) sampling lines, (1) scavenging kit.

 

Specifications

 

ECG
Number of Leads: 3 – or 5 Lead
Lead View: User-selectable; I, II, III, aVR, aVL, aVF, V (5-Lead);  I, II, or III (3-Lead)
Gain Selection: x0.5, x1, x2, and x4
Frequency Response: Diagnostic: 0.05 to 100 Hz (-3dB);
Monitor:  0.5 to 40 Hz (-3dB);
ST: 0.05 to 40 Hz (-3dB
Electrosurgery Protection: Yes
Defibrillator Protection: Yes
Pacer Detection/Rejection: Yes
ST Accuracy:  ±0.2 mm or ±5% of reading, whichever is greater, over heart range of 30 to 120 bpm
ST Range:  -6.0 to 6.0 mm

 

NIBP
Technique: Oscillometric upon in
Measurement Cycle: < 40 sec. typical
Auto. Measurement Cycles: 2, 3, 5, 10, 15, 30 min; 1, 2, 4 hr
Max. Allowable Cuff Pressure: Adult, pre-gelled, self-adhesive, disposable, non-polarized (identical pads can be placed in either position) defibrillation pads
Adult/Pediatric: 300 mmHg; Neonate: 150 mmHG
Range: Adult/Pediatric: 30 to 300 mmHg;
Neonate: 20 to 150 mmHg
Resolution: 1 mmHg
Transducer Accuracy: ±2 mmHg or ±2% of reading, whichever is greater, over full range
STAT Mode: 5 min of consecutive readings
Clinical Accuracy: Complies with AAMI
SP-10: 2002
1st 2nd

 

PULSE OXIMETRY
Range:  1% to 99%
Resolution: 1%
Accuracy: 70% to 99% range: ±2%; 50% to 69% range: ±3%; < 50%: unspeci
Method: Dual wavelength LED

 

HEART RATE (PULSE)
Source: User selectable: Smart, ECG, Pleth, NIBP, IBP
Range: 20 to 300 bpm (ECG, Pleth); 30 to 240 bpm (NIBP); 30-300 bpm (IBP)
Accuracy: ±1 bpm or ±1% (ECG) whichever is greater

 

TEMPERATURE
Channels: 2
Probe: YSI-700 Series
Range, Accuracy: 68° to 113°F (20° to 45°C): ±0.1°C
Probe: YSI-400 Series
Range, Accuracy: 150 mmHG
Range: 59° to 113° F (15 to 45 C)
Display Resolution: ±0.1°

 

RESPIRATION
Rate 6 to 150 bpm (ECG); 2 to 120
Resolution: 1 bpm
Accuracy: ±2 bpm or ±2%, whichever is greater
Source: User selectable: Smart, CO2, ECG

 

CAPNOGRAPHY (CO2)
Units: mmHg; %; kPa; Torr
Method: Non-dispersive infrared; autocalibrating
N2O Compensation: Manual (On/O
Range: 0 to 99 mmHg; 0 to 12.5%; 0 to 12.5 kPa; 0 to 99 Torr
Resolution: 1 mmHg; 0.1%; 0.1 kPa; 1 Torr Flow, Sample Rate: 200 ml/min
Accuracy: ±2 mmHg; ±0.3 vol. %; ±0.3 kPa; ±2 Torr or ±4% of reading, whichever is greater,  at 200 ml/min &  respiratory rate of ≤ 120 Br/min
Rise Time: 170 ms (10 to 90%) at 200 ml/min

 

IBP
Channels: 1 or 3
Transducer Sites: Selectable: ART, PA, LV, RV, LA, RA, CVP, ICP
Pressure Range: -10 mmHg to 300 mmHg
Transducer Freq. Response: 0 to 20 Hz; Impedance >300 ohms; Transducer
Sensitivity: 5µV/V/mmHg
Accuracy: ±1 mmHg or ±1%, whichever is greater

 

ALARMS
Indication: Audible; Visual (EN 60601-1-8)
Silence: Yes; 2 minutes or permanent

 

TRENDS
Memory: 24 hours at 30 second intervals
Display: Tabular, Graphical

 

DISPLAY
Screen: 12.1” active color touch screen
Resolution: Internal: 800 X 600 pixels
External: 800 x 600 pixels
Waveform: 6, maximum
Waveform Types: ECG leads I, II, III, aVR, aVL, aVF, V; CO2; Respiration; Pleth; IBP; breath-by-breath CO2; ST histograms; Mini-Trends; OXY-CRG
Sweep Speed: 6.25, 12.5, 25 or 50 mm/sec
Languages: English, Czech, French, German, Italian, Portuguese, Polish, Russian, Spanish, Turkish
Controls Keys: 10; membrane-activated
Rotary Knob: Push and rotate; 2 steps/turn

 

SYSTEM OUTPUTS
COM ports: Two RS 232 compatible DB9 ports; USB (for software downloads only)
Nurse Call: Contact switch; 3.5 mm stereo phone jack, 14 mm
Defib/Sync: BNC connector
Video Port: Serial VGA compatible
DC Out: 5 VDC output for optional wireless accessory
External Module Port: 8-PIN circular connector

 

PRINTER (OPTIONAL)
Type: Internal thermal line
Paper Speed: 12.5, 25 or 50 mm/sec

 

PHYSICAL PROPERTIES
Weight: 12 lbs; 5.4 kg
Size: 12” (H) x 14.5” (W) x 11.5” (D); 30.5 cm (H) x 36.8 cm (W) x 29.2 cm (D)

 

POWER REQUIREMENTS
Voltage: 100 to 240 VAC; 50/60 Hz
Power Consumption: 35 W, typical
Battery: 1 sealed lead acid
Power Consumption: 35 W, typical
Battery Life: 2 hours, typical (3 hours, typical for base unit)
Power Consumption: 35 W, typical
Recharge Time: 4 to 6 hours, typical

 

ENVIRONMENTAL
Operating Temperature: 32° to 104°F (0° to 40°C)
Storage Temperature: 23° to 122°F (-5° to 50°C)
Operating Humidity: 15% to 90%, noncondensing
Operating Altitude: -300 to 3,000 meters

 

CLASSIFICATION
Medical Device: Class II Equipment (IIb EU)
Electrical Protection: Class I Equipment
Degree of Protection: Type CF, Defibrillator-proof

Contact

U.S. CORPORATE HEADQUARTERS

333 Strawberry Field Rd Suite 11

Warwick, RI ,02886

T : 800 – 486 – 3849

Hours: 8:30 am to 5:30 pm Eastern Time

Accessories

ECG Accessories

Gas Monitoring Accessories

Learn More

  • This field is for validation purposes and should be left unchanged.